In most large air-conditioned buildings in Thailand, the chiller plant is the biggest single user of electricity. The good news is that much of its waste comes from how it is run, not from the equipment itself. These ten measures are the usual places to look, roughly in order of cost.
You cannot manage what you do not measure. Meter the power of the chillers, pumps and cooling-tower fans, and measure cooling output, so you know the plant's real efficiency (kW/TR) across the year. Every other step is judged against this number.
Many plants run more chillers than the load needs, each at poor part-load efficiency. Sequencing chillers to the actual load, and choosing which machines run at which loads, is often the cheapest saving available.
Every degree of higher chilled-water supply temperature reduces chiller work. Setpoints are often left low all year "to be safe". Resetting them with load and humidity, inside agreed comfort limits, saves energy without anyone noticing.
Chillers work less when the condenser water is cooler. Running cooling towers to deliver the lowest practical condenser temperature, balanced against tower-fan energy, improves whole-plant efficiency.
Pumps and fans that run at full speed regardless of load waste a lot of energy, because their power rises steeply with speed. Variable-speed drives on chilled-water pumps, condenser pumps and tower fans let them slow down at part load.
When chilled water returns only slightly warmer than it left, the plant has to pump far more water and run extra chillers. Common causes are faulty control valves, dirty coils and bypasses. Fixing them restores capacity and cuts pump energy.
Fouled condenser tubes and scaled heat exchangers force chillers to work harder. Regular tube cleaning, good water treatment and cooling-tower maintenance protect efficiency.
Align air-handling schedules with real occupancy, and turn off or set back systems serving unoccupied floors, ballrooms or wings.
Chillers, pumps and towers interact: slowing a pump can make a chiller work harder, and the reverse. Plant-wide optimisation software, such as Infinity CoolMaster's machine-learning CPMS, sets all of them together to minimise total plant power, continuously.
When chillers are old, inefficient or use phased-out refrigerants, replacement with a modern high-efficiency plant becomes the largest saving. With Cooling-as-a-Service it needs no capital: the provider funds, installs and runs the new plant, and you pay for efficient cooling from the savings.
Start with measurement and the no-cost operational measures, then invest where the data shows the largest losses. A free cooling audit from Infinity CoolMaster analyses 12 months of your bills and surveys your plant to show where the savings are, and our contracts guarantee a minimum 10% saving in writing.